Chimney Liner Installation in Port Hueneme

A liner is the pipe inside the brick that carries heat and exhaust out.

Ask About This Job

What the Visit Covers

Cracked clay tile, missing mortar between tiles and a flue that is the wrong size for a new insert are the three reasons we reline. The camera shows which one applies. We then size a stainless liner to the appliance outlet, run it from the connection to the top, seal the top plate and fit a cap. Insulation is added where the clearances call for it. Liners are quoted in writing.

Old flue filmed before sizing
Stainless liner sized to the appliance
Insulation where clearances need it
Top plate sealed and cap fitted

When a Clay Liner Has to Be Replaced

Clay tile liners last a long time when nothing goes wrong, and they fail for a few known reasons. A chimney fire, even a short one nobody noticed, heats the tiles unevenly and cracks them. Years of acidic condensation, especially from gas appliances venting into a flue sized for wood, wash out the mortar joints. An earthquake shifts tiles off their joints. Water from a cracked crown soaks them from the outside. Once a liner has cracks or open joints at several points, heat and exhaust can reach the brick and the framing around the chimney, and the flue is no longer safe to use. A camera scan shows exactly where the damage is. When it runs through more than a joint or two, or a new appliance needs a smaller flue than the clay one, a stainless liner is the usual answer.

We see three main reasons for relining in Port Hueneme, Oxnard and Camarillo. The first is a damaged clay liner in a wood-burning fireplace, where a stainless liner sized to the fireplace opening restores a safe flue. The second is a gas insert or a wood or pellet stove going into an old fireplace, where the appliance needs a liner sized to its outlet so its exhaust stays warm and drafts properly. The third is a gas furnace or water heater venting into an old masonry chimney after its partner fireplace was closed off, where the oversized clay flue lets exhaust cool and condense. In each case the liner is chosen for the fuel, the size is set by the fireplace or the appliance maker, and the job begins with a Level 2 scan, at $385.

What a Liner Installation Includes

A stainless liner is a continuous pipe from the fireplace or appliance to the top of the chimney. Rigid liner suits a straight flue, and flexible liner bends through offsets. For wood-burning fireplaces and stoves, the liner is usually wrapped in insulation or set in a poured insulating mix, which keeps the exhaust warm, cuts creosote and adds the clearance an older chimney may lack. At the bottom, the liner connects to the appliance collar or to a smoke chamber adapter for an open fireplace. At the top, a plate seals the old flue opening and a cap fastened to the liner keeps rain and animals out. Damaged clay tiles that block the path are broken out with care before the liner goes in. The quote lists the liner diameter, type, length, insulation, connectors, top plate and cap, each on its own line.

Liner work is quoted in writing after the scan, because the height of the flue, the offsets and the condition of the old tiles set the job. When the liner is in, we run a camera through it so you have stills of the new flue from bottom to top, and we photograph the connection and the top plate. If the liner serves a fireplace, we light a small test fire and check the draft; if it serves an appliance, we run it and take a carbon monoxide reading in the room. You get a closing note with the liner specs and the photos, which is the record a buyer's inspector or an insurer will want. Request a scan through the contact page and tell us what the chimney vents now and what you want it to vent.

  • Film, Then Quote
  • Sized to Fit
  • Priced by the Line
  • Proof of Hidden Work

Chimney Liner Installation by city

Each city page covers the houses, the weather and the flue problems we meet there, plus the ZIP codes on the run.

All cities we cover

No city matches that search. Try the next city over.

Flue and liner guides from Mosby Chimney Experts

Call (805) 250-1071